The RCM-810 Remote Control -Module is a optional module for supervision and remote control of power amplifiers. RCM-810 modules allow the integration of amplifiers into a remote control network with up to 100devices.
By using multiple networks within an IRIS-Net project up to 250 amplifiers can be used in total. Besides the network port, the RCM-810 also offers freely programmable control inputs and control outputs.
IRIS-Net module for remote control and supervision of DSA Series power amplifiers. This module provides very cost-effective integration of all 2-, 4- and 8- channel DSA Series power amplifiers into IRIS-Net networks allowing comprehensive remote control and supervision. Control features are: Configuration, Power ON/OFF, Power On Delay, Mute, Variable Load Drive Supervision parameters are: Load supervision for each channel, Output VU, Protect, Limit, Pilot tone, Temperature, Gain/Sensitivity. In addition a GPIO block allows for 2 Control Inputs, 2 Control Outputs, 2 Reference Outputs (+5 V, 200 mA / GND)
Installation (2 channel amp)
1. Switch the amplifier¡¯s power off and disconnect the mains plug 2. Remove the cover panel from the rear panel (2 screws) 3. Remove the amplifier top cover 4. Insert the RCM-810 module in the slot and lock it in place on the rear panel using the 2 screws (see illustration below) 5. Make the following cable connection using the 60 mm interconnection cord: CN4 on RCM- 810 module with CN3 on amplifier main board 6. Assembly the amplifier top cover 7. Set the module¡¯s CAN address using the ADDRESS selector switches 8. Connect the needed interfaces (CAN, Control Port) 9. Reconnect the mains cord and switch on the power amplifier, the RCM-810 module is automatically recognized by the amplifier. |
|